Create missing parameter configurations

New parameter configurations can be created for parameter definitions which are eligible, but for which no configuration can be found in the applicable context (displayed in red in the table).
  1. Choose for which criterion you want to create missing parameter configurations:
    CriterionLocation
    Resource Operation Production Management > Resource Types > Select Resource Type (Navigation Pane) > Select Resource (Navigation Pane) > Operations (Data Pane) > Instruction Parameters Overview
    Resource Type Operation Production Management > Resource Types > Select Resource Type > Operations > Instruction Parameters Overview
    Recipe Version Operation Recipe Management > Recipes > Select Recipe > Versions > Operations > Instruction Parameters Overview
  2. Click Create Missing Parameter Configurations . No selection needs to be made in the table. All eligible parameter definitions will be selectable in the wizard.
  3. Check the parameter definitions for which you want to create a parameter configuration in the applicable context. Where applicable, use the buttons Check All , Uncheck All , Check Selection , Uncheck Selection . Click Next.
  4. In the option group Parameter Definitions, the default values of the parameter configurations need to be set. The values which are in red in the table have no correct setting yet. Depending on the set data types (see Add a new parameter definition), the desired values can be entered in the following way:
    Option GroupExplanation

    Number

    A numerical standard value can be entered, and possibly upper and lower limits.
    • Enter the standard value under the option group Number Settings.
    • Max corresponds with the following values:
      • Setup instruction: maximum target limit
      • Data collection instruction: upper warning limit
      • Measurement instruction: upper control limit
    • Min corresponds with the following values:
      • Setup instruction: minimum target limit
      • Data collection instruction: lower warning limit
      • Measurement instruction: lower control limit
    • MaxMax corresponds with the following values:
      • Data collection instruction: upper error limit
      • Measurement instruction: upper specification limit
    • MinMin corresponds with the following values:
      • Data collection instruction: lower error limit
      • Measurement instruction: lower specification limit
    Text A free text can be entered as standard value.
    Flag A checked field or an unchecked field can be set as standard value.
    Date A date and possibly an hour can be set as standard value.
  5. Click Finish.